ARG83509
arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit (IL1 alpha, IL1 beta, IL6, IL8, GM-CSF, IFN-gamma, MCP1 and TNF-alpha)
arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit (IL1 alpha, IL1 beta, IL6, IL8, GM-CSF, IFN-gamma, MCP1 and TNF-alpha) for ELISA and Human
Immune System kit; Metabolism kit
Overview
Product Description | ARG83509 arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit (IL1 alpha, IL1 beta, IL6, IL8, GM-CSF, IFN-gamma, MCP1 and TNF-alpha) is an Enzyme Immunoassay kit for the quantification of IL1 alpha, IL1 beta, IL6, IL8, GM-CSF, IFN-gamma, MCP1 and TNF-alpha in serum, plasma and cell culture supernatant . See all Multiplex ELISA kits |
---|---|
Tested Reactivity | Hu |
Tested Application | ELISA |
Target Name | Inflammatory Cytokine Multiplex |
Conjugation | HRP |
Conjugation Note | Substrate: TMB and read at 450 nm. |
Sensitivity | IL1 alpha: 7.8 pg/ml IL1 beta: 3.9 pg/ml IL6: 7.8 pg/ml IL8: 11.7 pg/ml GM-CSF: 3.9 pg/ml IFN-gamma: 3.9 pg/ml MCP1: 7.8 pg/ml TNF alpha: 7.8 pg/ml |
Sample Type | Serum, Plasma and Cell culture supernatants |
Standard Range | IL1 alpha: 15.6 - 1000 pg/mll IL1 beta: 7.8 - 500 pg/ml IL6: 15.6 - 1000 pg/mll IL8: 23.4 - 1500 pg/mll GM-CSF: 7.8 - 500 pg/mll IFN-gamma: 7.8 - 500 pg/mll MCP1: 15.6 - 1000 pg/mll TNF alpha: 15.6 - 1000 pg/ml |
Sample Volume | 50 µl |
Application Instructions
Assay Time | 4.5 hour |
---|
Properties
Form | 96 well |
---|---|
Storage Instruction | Store components at 4°C or -20°C. Do not expose test reagents to heat, sun or strong light during storage and usage. Please refer to the product user manual for detail temperatures of the components. |
Note | For laboratory research only, not for drug, diagnostic or other use. |
Bioinformation
Background | Inflammation is body's protective response to foreign subjects, pathogens, tissue damage, autoimmune and other harmful stimuli. It is initiated by production of a cascade of chemicals and cytokines in affected area. These pro-inflammatory mediators result in vasodilation, increased vascular permeability, influx of blood, plasma leakage, neutrophil and macrophage infiltration and activation. Inflammatory reaction plays an important role in limiting foreign substance and engulfing pathogens and tissue debris. Acute inflammation is the initial phase to eliminate invaded foreign substances, pathogens and other harmful stimuli. If the stimuli persist, chronic inflammation will evolve. Progressive tissue destruction and shifting cell types occurs simultaneously during chronic inflammation. The cytokine profiles that regulate the procedure are different depending on the causes, location and progress of the inflammation. |
---|---|
Highlight | Related products: Inflammation antibodies; Inflammation Duos / Panels; Related news: HMGB1 in inflammation Inflammatory Cytokines Exploring Antiviral Immune Response New ELISA data calculation tool: Simplify the ELISA analysis by GainData |
Research Area | Immune System kit; Metabolism kit |
Images (9) Click the Picture to Zoom In
-
Antibodies Coating Pattern In Microtiter Plate of ARG83509 arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit (IL1 alpha, IL1 beta, IL6, IL8, GM-CSF, IFN-gamma, MCP1 and TNF-alpha)
-
ARG83509 arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit standard curve image
ARG83509 arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit results of a typical standard for Human IL1 alpha run with optical density reading at 450 nm.
-
ARG83509 arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit standard curve image
ARG83509 arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit results of a typical standard for Human IL1 beta run with optical density reading at 450 nm.
-
ARG83509 arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit standard curve image
ARG83509 arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit results of a typical standard for Human IL6 run with optical density reading at 450 nm.
-
ARG83509 arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit standard curve image
ARG83509 arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit results of a typical standard for Human IL8 run with optical density reading at 450 nm.
-
ARG83509 arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit standard curve image
ARG83509 arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit results of a typical standard for Human GM-CSF run with optical density reading at 450 nm.
-
ARG83509 arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit standard curve image
ARG83509 arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit results of a typical standard for Human IFN-gamma run with optical density reading at 450 nm.
-
ARG83509 arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit standard curve image
ARG83509 arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit results of a typical standard for Human MCP1 run with optical density reading at 450 nm.
-
ARG83509 arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit standard curve image
ARG83509 arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit results of a typical standard for Human TNF alpha run with optical density reading at 450 nm.
Title | Download Link |
---|---|
ARG83509 arigoPLEX® Human Inflammatory Cytokine Multiplex ELISA Kit User manual | Download |